国产精品日本亚洲777_午夜欧美日韩亚洲第一页大全_日本美女在线播放_国产日韩制服丝袜第一页_黑人av免费在线播放网址_国产亚洲精品色爽无码_自拍日韩精品第18页_在线va无码字幕丝瓜_精品va女神一区二区三区_亚洲欧美在线免费日

Conventional tuyere series

Wzhh / wzhi displacement air supply outlet

Wzhh / wzhi displacement air supply outlet

The wzhh and wzhi type displacement air supply tuyeres are especially suitable for the situations where the indoor cooling and heating load changes greatly. In these situations, sometimes it needs to supply cold air, sometimes it needs to supply isothermal air or hot air.

Wzhh and wzhi series displacement air supply tuyeres can be used for both heating and cooling conditions. The position of the air flow regulating plate is adjusted manually or automatically by the zipper actuator to realize the conversion of heating or cooling conditions.

Wzhh and wzhi series displacement air supply tuyeres are generally suspended and installed in the plant to facilitate the passage of mechanical equipment in the lower area. The cooling air is supplied horizontally at low speed and low turbulence, while the heating air is supplied downward at a higher speed. Because they are installed in a higher position, generally 3-10m, the temperature difference of the air supply is larger than that of the conventional displacement ventilation, which can be - 8 ~ + 12 ℃.

Explain:

The displacement ventilation tuyere with circular structure is suitable for hanging and installing in the large space area which needs cooling in summer and heating in winter.

Wzhh low turbulence air supply, almost no induction, suitable for application in the Department of air quality requirements of large space.

There is an opening at the lower part of wzhi. When heating in winter, most of the air flow is sent out from the upper part.

 

 

The wzhh and wzhi type displacement air supply tuyeres are especially suitable for the situations where the indoor cooling and heating load changes greatly. In these situations, sometimes it needs to supply cold air, sometimes it needs to supply isothermal air or hot air.

Wzhh and wzhi series displacement air supply tuyeres can be used for both heating and cooling conditions. The position of the air flow regulating plate is adjusted manually or automatically by the zipper actuator to realize the conversion of heating or cooling conditions.

Wzhh and wzhi series displacement air supply tuyeres are generally suspended and installed in the plant to facilitate the passage of mechanical equipment in the lower area. The cooling air is supplied horizontally at low speed and low turbulence, while the heating air is supplied downward at a higher speed. Because they are installed in a higher position, generally 3-10m, the temperature difference of the air supply is larger than that of the conventional displacement ventilation, which can be - 8 ~ + 12 ℃.

Explain:

The displacement ventilation tuyere with circular structure is suitable for hanging and installing in the large space area which needs cooling in summer and heating in winter.

Wzhh low turbulence air supply, almost no induction, suitable for application in the Department of air quality requirements of large space.

There is an opening at the lower part of wzhi. When heating in winter, most of the air flow is sent out from the upper part.

Hot recommendation

Wdxf-b flat swirl tuyere

Wdxf-b flat swirl...

View details
Watcd-f temperature sensing circular diffuser

Watcd-f temperatu...

View details
Wdbf-c floor diffuser

Wdbf-c floor diff...

View details